The Responses page defines the actions that adTempus should take in response to events that are fired during execution of the step.
Responses List
The Responses list lists the responses that have been specified for the step. You can add, edit, delete, or reorder responses. See the Responses topic for more information on the available responses.
The following events are defined for the Computer Shutdown task:
Event |
Description |
Beginning of step |
Occurs at the beginning of the step, before adTempus has evaluated any conditions or attempted to execute the task. |
Condition(s) failed |
Occurs if one or more conditions is not met (occurs only once regardless of how many conditions failed). |
End of step |
Occurs at the end of the step, regardless of the step's outcome. |
Job aborted |
Occurs when the job is aborted (manually or as a result of a Job Control action). |
Restart limit exceeded |
Occurs when the step is being restarted by a Job Control action but the restart limit specified on that action has been exceeded. |
Step failed |
Occurs when the step's status is being set to Failed, for whatever reason. |
Step is being restarted |
Occurs when the step is being restarted by a Job Control action. |
Step skipped |
Occurs when the step is skipped because conditions were not met (if the Skip... option is selected on the Conditions page). |
Shutdown could not be initiated |
Occurs if shutdown could not be initiated (for example, if the user account used for the job does not have the necessary permission). |
Shutdown initiated |
Occurs once shutdown has been successfully initiated. |
See Also
Computer Shutdown Task Properties
Computer Shutdown Task Overview